FEATURES
  • Balance load sharing design for power redundancy with zero transfer time
  • When eight one of the redundant power supplies fails or breaks down, you can easily replace failed unit without any interface to the system.
  • A warning buzzer to indicate any one of the power supplies fails.
  • The warning LEDs are provided
  • Typical Efficiency is 70% at full load
  • 0oC ~ 50oC Operating temperature; 10%~90% RH Humidity
  • Safety meets UL/CSA/TUV
  INPUT CHARACTERISTICS

VOLTAGE

90 - 132 VAC / 180 - 260 VAC SWITCHABLE
FEQUENCY 47 - 63 Hz
INPUT CURRENT 3.0A / 1.5A PER UNIT (PARALLEL), 6.0A / 3.0A (ONE POWER)
INRUSH CURRENT 40A MAX. FOR 110 VAC, 80A MAX. FOR 220VAC
  OUTPUT CHARACTERISTICS
OUTPUT
VOLTAGE
OUTPUT CURRENT REGULATION OUTPUT
MIN.[A] MAX.[A] LOAD LINE RIPPLE & NOISE MAX.[P.P]
+5V 7.0 25/7~32* +-5% +-1% 50mV
-5V 0 0.5/1.0* +-11% +-1% 150mV
+12V 2.5 14/19~24* +-6% +-1% 100mV
-12V 0 0.5/1.0 +11%~-10% +-1% 150mV
+3.3V** 1.0 2.0 +-5% +-1% 50mV
  SPECIFICATION
TEMPERATURE RANGE OPERATING 0oC -- 50oC; STORAGE -20oC -- 80oC
TRANSIENT RESPONSE OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX.
FOLLOWING A 50% LOAD CHANGE
HOLD UP TIME 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
HUMIDITY 10 ~ 90% RH
EFFICIENCY 60% TYPICAL, AT FULL LOAD
POWER GOOD SIGNAL ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION 130 ~ 150% MAX.
OVER VOLTAGE PROTECTION +5V ‡ 5.5V ~ 7.0V, 3.3V: 3.8V ~ 4.5V
OVER CURRENT PROTECTION SHORT CIRCUIT
ALARM METHOD 1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE SIGNAL
EMI NOISE FILTER AC INPUT LINE FILTER FOR FCC CLASS B ON EACH POWRE UNIT ARE AVAILABLE UPON ORDER
SAFETY UL / CSA / TÜV APPROVAL
HOT-SWAPPABLE / HOT-PLUGGABLE CAPABILITY
DIMENSION 195.0 (D) x 356.00 (W) x 99.0 (H)

REDUNDANCY

BALANCE SHARE LOAD METHOD

  Ordering Information
Model Description

RAH-4300

300W Hot-Swap Redundant Power Supply

RAH-4400

400W Hot-Swap Redundant Power Supply