| SPECIFICATION |
| TEMPERATURE RANGE |
OPERATING 0oC -- 50oC; STORAGE -20oC -- 80oC |
| TRANSIENT RESPONSE |
OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX.
FOLLOWING A 50% LOAD CHANGE
|
| HOLD UP TIME |
16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE |
| DIELECTRIC WITHSTAND |
INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
|
| HUMIDITY |
10 ~ 90% RH |
| EFFICIENCY |
60% TYPICAL, AT FULL LOAD |
| POWER GOOD SIGNAL |
ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms |
| OVER LOAD PROTECTION |
130 ~ 150% MAX. |
| OVER VOLTAGE PROTECTION |
+5V 5.5V ~ 7.0V, 3.3V: 3.8V ~ 4.5V |
| OVER CURRENT PROTECTION |
SHORT CIRCUIT |
| ALARM METHOD |
1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE SIGNAL |
| EMI NOISE FILTER |
AC INPUT LINE FILTER FOR FCC CLASS B ON EACH POWRE UNIT ARE AVAILABLE UPON ORDER |
| SAFETY |
UL / CSA / TÜV APPROVAL |
| HOT-SWAPPABLE / HOT-PLUGGABLE CAPABILITY |
|
| DIMENSION |
195.0 (D) x 356.00 (W) x 99.0 (H) |
|
REDUNDANCY
|
BALANCE SHARE LOAD METHOD |
|
|