| FEATURES |
- Designed for fault-tolerant applications
- Suitable for disk array and rack-mount computers
- The most compact design which conforms to PS/2 type power supply dimensions
- Minimum efficiency is 75%
- 10 to 50% operating temperature; 20 to 90% RH humidity
- 50,000 hrs at 25oC MTBF calculated by MIL217E
- Safety Standards meet UL, CSA, TUV, CE
- EMI Standards meet FCC Class, VDE
|
| INPUT CHARACTERISTICS |
| Input Voltage |
90V to 132V AC(115V) or 180 ~ 264V(230V)
-38V to -57V DC for BPS-250RDD |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
6A for 115V AC / 3A for 230V AC / 8A for -48V DC(BPS-250RDD) |
|
| OUTPUT CHARACTERISTICS |
| Model |
Output Voltage |
Load Current |
Tolerance |
| Min |
Max |
Total |
|
BPS-250RD
BPS-250RDX
|
+5V |
3A |
30A |
200W |
+-5% |
| +12V |
1A |
14A |
+-5% |
| +3.3V* |
0A |
20A |
+-5% |
| -12V |
0A |
0.5A |
10W |
+-10% |
| -5V |
0A |
0.5A |
+-10% |
| +5V SB* |
0.1A |
1A |
3.5W |
+-5% |
| *+3.3V & +5VSB is for BPS-250RDX, BPS-270RDX and BPS-250RDDX |
|
|
|
|
|
|
| SPECIFICATION |
| Protection Type |
- Overload Power: Shutdown all DC outputs when +5V and +12V outputs are overload to the limit 120%, under condition of 90/180V input
- Over Voltage: Latch off if the +5V or +12V maximum voltage exceeds the limit 5.8¡Ó0.65V for +5V, 12.6~15.6V for +12V, under condition of all operating
- Short circuit: A short circuit placed on any output shall cause no damage to this unit
|
| Overshoot |
Any output overshoot at turn-on shall not exceed 10% of nominal voltage value |
| Hold Up Time |
Minimum 16ms |
|
|